| Motor Connecting Cables | |||
| 2YSLCY-JB/2YSLCYK-JB | 9YSLCY-JB | PENDANT CABLE |
Mineral insulated cables
Self-regulating Heating Cable Type ELSR-N up to 80°C
Application
Frost protection
Heat tracing on level indicators
Chemical & petrochemical industries
Tank bottom heating of LNG storage tanks
Pipe heat tracing
Vessels and tanks
Automotive
Food processing industry
Standard
EN 62395-1
Voltage Rating
230V
CABLE CONSTRUCTION

Bus wire: Nickel plated copper.
Self-regulating heating element
Insulation: Thermoplastic.
Protective: Tinned Cu braid.
Outer sheath: Thermoplastic or fluoropolymer.
Mechanical and Thermal Properties
Maximum maintenance temperature: 65℃
Maximum exposure temperature: 85℃
Minimum installation temperature: -51℃
Minimum bending radius: 25 mm
Cable Parameter
APPROX. |
Nominal output at 10℃ |
APPROX. |
|---|---|---|
13.6×5.5 |
10 |
91 |
14.1×5.8 |
10 |
108 |
13.8×5.6 |
10 |
108 |
13.6×5.5 |
20 |
91 |
14.1×5.8 |
20 |
108 |
13.8×5.6 |
20 |
108 |
13.6×5.5 |
30 |
91 |
14.1×5.8 |
30 |
108 |
13.8×5.6 |
30 |
108 |
13.6×5.5 |
40 |
91 |
14.1×5.8 |
40 |
108 |
13.8×5.6 |
40 |
108 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information